For documentation on the current version, please check Knowledge Base.
Orbit Enterprise Service
This page is a glossary and bundles technical information about the Orbit EOS Service and its HTTP Web Service.
EOS enables corporate management of users, permissions, workspaces, and licenses. It is the backbone for Orbit 3DM Feature Extraction Client-Server setups and Orbit 3DM Publisher.
Amazon S3 Bucket Cloud Storage Configuration
Orbit EOS configuration to connect and load resources from Amazon S3 Bucket cloud blob storage.
- File:
../server/program/config/amazon.store.<config.name>.ini
- Parameters
- Most parameters are self-explaining.
- config.name: Orbit configuration name for the cloud storage. Free of choice, lower case, no special characters.
Use the prefixam:/<config.name>/
in the resource file path to access the root folder of the AWS Bucket. - region.name: Amazon regional endpoint code, see https://docs.aws.amazon.com/general/latest/gr/rande.html
type amazon access.key xxx secret.key xxx region.name xxx bucket.name xxx readonly true cache true cache.expire.time 172800.0 file.content.read.thread.count 12
Azure Container Cloud Storage Configuration
Orbit EOS configuration to connect and load resources from a Microsoft Azure Container cloud blob storage.
- File:
../server/program/config/azure.store.<config.name>.ini
- Parameters
- Most parameters are self-explaining.
- config.name: Orbit configuration name for the cloud storage. Free of choice, lower case, no special characters.
Use the prefixaz:/<config.name>/
in the resource file path to access the root folder of the Azure Container. - region.name: Regional endpoint code
account.name xxx account.key xxx container.name xxx readonly true region.name xxx
Cross Domain Communication
When embedding and accessing an Orbit Flash WebClient via another server in another domain, cross-domain communication needs to be authorized by the Orbit Publisher HTTP Web Service.
This is authorization is required by use of Adobe Flash, more information :
Server configurations
Cross-Domain configurations are applied at loading the Flash WebClient. To update this configuration the Orbit Service doesn't need to be restarted.
../server/program/wwwroot/crossdomain.xml
The example below will authorize all cross domain communication :
<cross-domain-policy> <site-control permitted-cross-domain-policies="all" /> <allow-http-request-headers-from domain="*" headers="*" secure="false"/> <allow-access-from domain="*" secure="false"/> </cross-domain-policy>
Download Time-Out
Configuration to set URL to connect and download time-out.
- File :
../server/program/config/server.ini
- Parameters :
urldownloader.timeout.connect
urldownloader.timeout.read
- Value : Milliseconds as integer value
- Default Value : 60000
urldownloader.timeout.connect 120000 urldownloader.timeout.read 120000
DOX
Desktop Client-Server Communication
The Orbit toolkit is network-neutral. Connectivity requires an IP-resolve system (such as a DNS). The Data Orbit eXchange protocol or shortened “DOX” protocol is Orbit's proprietary communication protocol between the Orbit tiers.
DOX requires only 1 port to be accessible from the outside. Firewalls thus need only to open 1 port to allow remote access to an Orbit server system (in contradiction to standard Java RMI connectivity).
DOX is a compressed and binary way to do the communication between Orbit Client and Orbit Server in the most secure, simple, and fast way. It has no relation with HTTP or the alikes, but of course, runs over Tcp/Ip.
DOX does not influence any other protocol and cannot be hacked.
All Orbit Products are able to access remote EOS resources and instantly become client/server applications, providing access to corporate resources. Most Orbit products are available both in Standalone as in Client-Server.
EOS Install
EOS is a running operating system service and is preferably installed and started using an OS administrator account. The used account must have full permission to read and write into the entire Orbit server installation directory. Read access is required for all resources used by EOS.
A proper EOS service start, stop and remove are possible as OS administrator using the Orbit shortcuts within the Orbit installation directory :
../server/program/bin/
Stop & Start
When updating the Orbit Server software or applying hardware maintenance it will be required to stop and restart the Orbit Service. The service needs to be installed before starting and stopped before removing.
Use of the Orbit Service shortcuts is recommended at all time, verify successful Service Install, Start, Stop and Remove using the OS Services Management Console.
Multiple instances
The name of an operating system service supposed to be unique.
To install multiple Orbit Services on a single server the Orbit Service Name of the second instance will need to be renamed before installing :
- Windows :
../server/program/bin/ServiceInstall.bat
.. set SERVICE_DISPLAY_NAME=Orbit Enterprise Service 2 set SERVICE_DESCRIPTION=The Orbit application service 2 ... .. //IS//Orbit_2 ..
EOS Logging
The activity and tasks completed by the EOS service are logged by default into following directory :
../server/log/eos/
These log files contain only the most recent activity of the EOS service. For reasons of disk space, only 10 files of 8MB each are stored. The most recent log file has no index suffix.
Server Configurations
Orbit Server configurations are applied at Service Start. To update this configuration the Orbit Service must be stopped and restarted after changing the configurations.
../server/program/config/server.ini
system.logfile <SYSTEMPATH>/log/eos/server.log system.logfile.pagecount 8 system.logfile.pagesize 16 system.logall true
File Access and Permission
The Orbit EOS service reads all resource requested by Orbit Clients and read & writes configurations as set by the EOS Console.
Consequently, Orbit EOS Service requires read access on all used resource files and read & write access to all Orbit setup and configuration files.
Access to network resources
Special attention is required regarding file access permissions for the Operating System User running the EOS service.
Additional note on Windows, Mapped Network Drives are not available to Operating System Services, use of Uniform Naming Convention (UNC) is required.
When adding resources to EOS, using the Publisher Console or legacy EOS console ensure the EOS service has access to the added resources at all time.
Access to system configuration files
Disk space or file access issues on EOS configuration files will result in corrupted configurations and software malfunction. Ensure there is enough disk space and all EOS configuration files are accessible at all times.
User Account in Server Configurations
Orbit EOS Service account settings are applied at Service Install.
One can use the Operating System services management console to update the User Account or add User credentials into the Orbit service installation files.
Configuration update on the Service installation files requires the Orbit Service to be be stopped, removed, updated, re-installed, and restarted. Verify the update using the OS Services Management Console.
../server/program/bin64/ServiceInstall.bat
set SERVICE_USER=--ServiceUser=<Domain>\<UserName> --ServicePassword=<UserPassword>
HTTP Proxy
The default configurations for all outgoing HTTP and HTTPS requests can be updated. However, we do advise using the default operating system proxy settings.
Proxy configurations are applied at Service Install. To update this configuration the Orbit Service must be stopped, removed, updated, re-installed, and restarted.
Add the following Java VM arguments into :
- Linux :
../server/program/bin/wrapper.conf
>Java Additional Parameters
- Windows :
../server/program/bin/ServiceInstall.bat
>JAVA_OPTIONS
Set system proxy settings
-Djava.net.useSystemProxies=true
Set other proxy settings
Below for https, for http replace “-Dhttps” by “-DHttp” :
-Dhttps.proxyHost=0.0.0.0 -Dhttps.proxyPort=0000 -Dhttps.proxyUser=xxx -Dhttps.proxyPassword=xxx
Https example for Linux :
# Java Additional Parameters wrapper.java.additional.1=-Xrs wrapper.java.additional.2=-Djava.awt.headless=true wrapper.java.additional.3=-Dhttps.proxyHost=0.0.0.0 wrapper.java.additional.4=-Dhttps.proxyPort=0000 wrapper.java.additional.5=-Dhttps.proxyUser=xxx wrapper.java.additional.6=-Dhttps.proxyPassword=xxx
When using a proxy that doesn't require user validation, parameters “proxyUser” and “proxyPassword” should not be added.
HTTP Workthreads
The default number of concurrent Threads is 32 and a backlog of 64 Tasks.
Related to the available Cores the number of concurrent threads and backlog tasks can be increased.
Server Configurations
Work thread configurations are applied at Service Start. To update this configuration the Orbit Service must be stopped, updated and restarted.
../server/program/config/server.ini
portserver.HTTP.workthread.count 32 portserver.HTTP.maximum.pending.requests 64
HTTPS
WebClient - Server communication
The Orbit Publisher includes an HTTP or HTTPS Web Server. One or the other, not both together. Incoming HTTP requests can be redirected to HTTPS services
By default, an HTTP Web Service is configured. Below the documentation on how to configure an HTTPS Web Service.
The Http(s) Web Service is used for Publisher WebClient (“Publication”) - Server and EOS WebClient (“EOS Console”) - Server communication.
KeyStore File
Orbit supports both PKCS 12 and Java KeyStore files.
The password-protected KeyStore file must contain your Private Key and full Certificate Chain from Root to Public Domain Certificate.
Certificate submitting and KeyStore file creation must be completed prior to configuring the Orbit Web Server from HTTP to HTTPS.
More information, see Wikipedia Authorization Certifcate, Wikipedia Public Key, Wikipedia Java Keystore, Wikipedia PKCS 12.
Server configurations
These Web Server configurations are applied at Service Start. To update this configuration the Orbit Service must be stopped, updated and restarted.
KeyStore file
Copy the KeyStore file keystore.xxx
to ../server/program/services/http/
.
Supported KeyStore files : .jks, .jceks, .p12, .pks, .pfx
KeyStore file Password
Add a keystore.pwd
single line text file next to the KeyStore file.
The password can be saved as plain text or scrambled, contact Orbit Support.
HTTPS Service
Configure the HTTP service to operate in HTTPS mode :
../server/program/services/http/service.ini
Parameter=secure:true
Port
In the same service.ini
file, modify the port to 443:
Parameter=port:443
Redirecting from HTTP to HTTPS
To redirect an existent from HTTP to HTTPS , the procedure described below must be followed:
A new folder http80
must be created and placed in:
* ../server/program/services
The folder must containing a service.ini
file prepared as the example:
Services= Service= Name=HttpService80 ClassName=com.orbitgis.toolx.network.interfaces.http.server.HTTPService Parameters= Parameter=secure:false Parameter=host:all Parameter=port:80 Parameter=http.get.enable:false Parameter=http.get.wwwroot:<SYSTEMPATH>/wwwroot Parameter=run.service.enable:false Parameter=redirect.to.secure:true
Additional configuration consequences
For Orbit Publisher EOS-Console users only:
- Enable secure cross-domain communication, see above HTTP Cross-Domain Communication.
- Configure geocoding plugins to communicate via secure HTTPS connection to avoid HTTP-HTTPS netwerk security conflicts.
See Publisher Customized Publications. - Ensure the Publication Server Url is available via HTTPS , see EOS Console > Publishers > Main > Publish.
Port Allocation
By default the EOS service uses TCP port 1100 (DOX), the Orbit Web Service requires port 1111 (HTTP)
Communication between Client and Server must be available at all times. A client, server, or network blocking firewall on these ports will result in run time errors.
The default server and port configuration can be changed if required. However, we do advise to use a reverse proxy instead.
Server Configurations
Port configurations are applied at Service start. To update this configuration the Orbit Service must be stopped, updated, and restarted.
Server side Service configuration files :
../server/program/services/dox/service.ini
../server/program/services/http/service.ini
Client Configurations
Desktop Client side configuration file :
../client/program/login.ini
Port Logging
The activity on Dox and HTTP ports can be logged (default “false”) into following directory :
../server/log/portserver/
Server Configurations
Portserver logging configurations are applied at Service Start. To update this configuration the Orbit Service must be stopped, updated, and restarted.
../server/program/config/server.ini
portserver.logging.enabled false portserver.logging.interval 10 portserver.logging.location <SYSTEMPATH>/log/portserver/<TIMESTAMP>.log
Procrun Service
On Windows Orbit uses the Procrun Service to start and run the EOS Service.
The Procrun Service creates by default 2 log files :
C:/Windows/System32/LogFiles/Apache/name-stderr.date
> e.g. “orbit-stderr.2015-04-14” : Log of service installC:/Windows/System32/LogFiles/Apache/nname-stdout.data
> e.g. “orbit-stdout.2015-04-14” : Log of Procrun Service used by Orbit
The sum of all these files can become very big and may result in the C:/ partition running out of space. Disable this service logging to avoid a relatively small C partition to run out of space.
To disable Procrun logging following server-side configuration file must be updated.
Server Configurations
Procrun Service configurations are applied at Service Install. To update this configuration the Orbit Service must be stopped, removed, updated, re-installed and restarted.
Verify the User Account “Orbit Enterprise Service” before removing the service. Check the service credentials at the “Log On” panel of the Operating System Service “Properties” window. Before restarting the Orbit Service, it is required to change the credentials back to the actual configuration.
- Windows :
../server/program/bin64/ServiceInstall.bat
Logging enabled :
--StdOutput=auto --StdError=auto
Logging disabled :
--StdOutput= --StdError=
Test Services
The availability of the HTTP Web Service or a specific Publication can be verified by requesting respectively the Web Service cross domain configuration or the publication html web page :
http://<server>:<port>/publications/<publication>/index.html
http://<server>:<port>/crossdomain.xml
A TestService is available to request detailed runtime information about all EOS Services. Optionally a TestMask can be applied. Below the example for “StartTime”.
http://<server>:<port>/?service=TestService&request=RunTestOperation
http://<server>:<port>/?service=TestService&request=RunTestOperation&TestMask=ServiceContainer.System.StartTime
WMS and WFS Hosting
The Orbit EOS server includes the capability to provide OGC compliant WFS (version 1.1.1) and WMS (version 1.1.0) services for EOS Resources.
More information about the OGC WFS and WMS specifications :
Customization of the Orbit WMS and WFS services can be achieved via the configuration.xml file. Next to some service settings and specifications, the list of available layers can be restricted.
When removing this configuration.xml file :
- a default set of service settings and specifications will be used
- user authentication will be required at all time
- the list of available layers will be set to all dataset for which the user has EOS view permissions
Server Configurations
WMS and WFS configurations are applied at Service Start. To update this configuration the Orbit Service must be stopped, updated, and restarted.
../server/program/services/wfs/configuration.xml
../server/program/services/wms/configuration.xml
Example for WFS
This example includes all available tags to configure the Orbit WFS service.
<Configuration> <URLPrefix>wfs</URLPrefix> <ServiceTitle>Orbit WFS</ServiceTitle> <ServiceAbstract>Web Feature Service powered by Orbit GT Technology</ServiceAbstract> <ServiceKeyword>Orbit GT</ServiceKeyword> <ServiceKeyword>EOS Resources</ServiceKeyword> <ServiceProviderName>Orbit GT</ServiceProviderName> <ServiceProviderSite>https://orbitgt.com</ServiceProviderSite> <DataSet> <DataSetName>Flanders_Buildings</DataSetName> </DataSet> <DataSet> <DataSetName>Flanders_Parcels</DataSetName> </DataSet> <CRS>31370</CRS> <CRS>3395</CRS> <CRS>4258</CRS> <CRS>4326</CRS> <FixedUsername>guest</FixedUsername> <FixedPassword>guest</FixedPassword> <IsMaxFeaturesEnabled>true</IsMaxFeaturesEnabled> <DefaultMaxFeatures>10000</DefaultMaxFeatures> </Configuration>
Example for WMS
This example includes all available tags to configure the Orbit WMS service.
<Configuration> <URLPrefix>wms</URLPrefix> <ServiceTitle>Orbit WMS</ServiceTitle> <ServiceAbstract>Web Map Service powered by Orbit GT Technology</ServiceAbstract> <ServiceKeyword>Orbit GT</ServiceKeyword> <ServiceKeyword>EOS Resources</ServiceKeyword> <ServiceRootLayerTitle>Cadastral maps of Flanders</ServiceRootLayerTitle> <DataSet> <DataSetName>Flanders_Buildings</DataSetName> <Abstract>Buildings of Flanders</Abstract> </DataSet> <DataSet> <DataSetName>Flanders_Parcels</DataSetName> <Abstract>Parcel of Flanders</Abstract> </DataSet> <CRS>31370</CRS> <CRS>3395</CRS> <CRS>4258</CRS> <CRS>4326</CRS> <FixedUsername>guest</FixedUsername> <FixedPassword>guest</FixedPassword> </Configuration>
Tags
For some reason the tags available for WFS and WMS differ, for any explanation see OGC documentation.
Some notes about special tags or values used by Orbit :
- URLPrefix : <server url>:<port>/<URLPrefix>?service=<“wms”/“wfs”>&request=getcapabilities
- DataSetName : EOS Dataset Registry Name
- FixedUsername, FixedPassword : EOS Username and Password to access Service. If not set, the username and password will be requested upon accessing the service. The fix or entered user must have EOS permissions to view the configured resources to get access to this resource.
- IsMaxFeaturesEnabled : Highly recommended setting to restrict the maximum number of features that can be replied to on a single feature request.
Workspace configurations
As optional server side configuration it is possible to use a dedicated set of configurations for a given service depending on the used Orbit desktop client workspace.
All server-side service configurations are grouped in the according properties.ini or properties.xml configuration file. It is possible to create a separated “properties_<workspace>” service configuration file for any known Orbit workspace. This duplicated service configuration file makes it possible to set private service configurations for a given workspace.