Post Collection Calibration


This page describes how to use the extension “Post Collection Calibration” in the Orbit 3DM Content Manager.

Content Manager
Main Toolbar > Extensions > Post Collection Calibration

If point cloud overlay on imagery is not perfect, depending on the nature of the observable shift, the Post Collection Calibration Extension can be used to improve the pointcloud and imagery matching.
Do not start the Post Collection Calibration process if the requirements described in the Concepts bellow are not met.

Concepts

Image Positions and Orientations
In order for an image to be displayed correctly, the position and orientation of the sensor at the moment of exposure must be known.
The orientation model of the reference frame must be understood and data must be imported accordingly.
Read more about this topic in: Image Positions and Orientations
The Post Collection Calibration Extension cannot be used to improve matching between pointcloud and imagery if the position and orientations are not imported correctly. The workflow chapter bellow explains how to check if the import is correct.
If the import is correct, the extension can correct original position and orientation parameters if they are unknown or incorrect, by recomputing the X,Y,Z lever arms and the Pan, Tilt and Roll boresight offset values. Bellow this parameters will all be generically named lever arms.

Shift types
Shifts between the overlaid pointcloud and imagery can be constant throughout the run or variable from image to image.
Variable shifts, for example due to incorrect pre-processing of data, cannot be solved using the Post Collection Calibration.
Constant shifts are a result of missing or incorrect lever arms applied on importing data, and can be solved using the Post Collection Calibration extension.
The workflow chapter bellow explains how to check the nature of an visible shift .

Calibration Points
The calibration points are point vector representations of objects location that can be readily and clearly identified on both imagery and pointcloud.

Cameras

Choose camera
Choose the camera to calibrate. Calibration can use only original (e.g. .jpg) imagery. The camera cannot be chosen if any optimized imagery is stored in the run.

Inspect

The inspect “Photo Debugger” tool offers the possibility to approximate the corrections needed to calibrate an image.
This is only an empirical method, that allows the user to find an approximation of required lever-arms corrections. However, it can be very useful, it offers a rapid and easy way to identify if lever-arms corrections can improve the data matching.
For a rigorous mathematical lever-arms correction, see Calibration points bellow.

Photo Debugger

Calibration points

Camera Leverarm

Post Collection calibration Workflow

Verify Original import

Mandatory

Find approximate lever arms manually

Optional, can be used to roughly correct large shifts

Enter and apply found values

Mandatory if Photo debugger was used and good approximate lever arms were found.

Calculate lever arms using reference points

Mandatory

Enter and apply calculated values

Mandatory if lever arms were calculated