[[112:photogrammetry:strabo:processing_triangulation:index|{{ :orbitgis:return_overview.png|Return to Overview - Triangulate Process}}]]
======Interior Orientation=======
\\
{{photogrammetry:strabo:processing_triangulation:interiororientation:status_interiororientation.png?nolink|}}
|
In this status section, three functions are available to determine the IO (Internal Oriƫntation) for all images in the project:\\ \\
* Edit fiducial marks...
* Remove fiducial marks from project...
* List fiducial marks...
|
\\
-----
\\
__**Edit Fiducial Marks**__ : This subject is identical to and explained in the Project Wizard Step 6 [[112:photogrammetry:strabo:project:create:projectwizard|'Interior Oriƫntation']].
\\ \\ \\
__**Remove Fiducial mark from Project**__ : This function opens the following dialog...
\\
{{ photogrammetry:strabo:processing_triangulation:interiororientation:delete_fiducial_mark.gif?nolink|}}
|
* Enter the number of the fiducial mark you want to delete from all the images.
* Press the button 'OK' to delete the requested fiducial mark.
|
Use this functionality only if you find a systematic error on one of the fiducials.
\\ \\
**__List Fiducial Marks__**
This function creates a txt file with information regarding the accuracy on the fiducial marks, for every image in the project. The below-mentioned dialog will popup. At the end of the file you will find a summary with the accuracy and number of fiducial marks, per image. From the beginning of this file, a full transformation report is listed for each image. Press the 'Save as' button to save the file.
{{photogrammetry:strabo:processing_triangulation:interiororientation:fiducial_marks_listing.gif?nolink|}}